• RecommendMORE

    Off grid VMII Plus 3.5KW /5KW MPPT so

    Off grid VMII Plus 3.5KW /5KW MPPT so

    3 Phase Online UPS

    GH 33 10KVA-30KVA

    Date:2020-06-25
    Share

     

     
                   3 phase in & out - ture double conversion 10Kva - 30KVA Online UPS

        

    Product Features:
     
    * True double-conversion
    * DSP technology guarantees high performance
    * Output power factor 0.8
    * Wide input voltage range
    * 50Hz/60Hz frequency converter mode
    * ECO mode operation for energy saving (ECO)
    * Emergency power off function (EPO)
    * Generator compatible
    * SNMP+USB+RS-232 multiple communications
    * 3-stage extendable charging design for optimized battery performance
    * Optional maintenance bypass switch
    * Optional N+X parallel redundancy
    * Optional isolation transformer offers full isolation and complete common mode noise rejection   
    * Accepts dual power inputs








    Specifications:

    Model   3C10K(S) 3C15K(S) 3C20K(S) 3C30K(S)
    Phase     3 phase in 3 phase out   
    Capacity   10000VA/8000W  15000VA/12000W  20000VA/16000W  30000VA/24000W 
    Input    Rated voltage 3*400VAC (3ph+N)   
     Voltage range  305-478VAC(3-phase)@100% load190-520 VAC(3-phase)@50% load  
     Frequency range  46-54Hz or 56-64Hz    
     Power Factor  ≥0.99 @100% load    
     Output            Output voltage 208/220/230/240VAC    
        Voltage range(Batt.mode) ±1%    
     Frequency range
    (Synchronization correction range)
    46-54Hz@50Hz/56-64Hz@60Hz    
           Frequency range (Batt.mode) 50hz ± 0.1hz or 60hz ± 0.1hz
       Surge ratio    3:1(max)
        Harmonic distortion   ≤2% THD( linear load);
    ≤5%THD(Non-linear load
     Transfer time  AC to DC 0
     Inverter to Bypass 0    
     Wave form  Pure sine wave    
    Efficiency 
     
    AC mode  89% 89%   89% 90% 
    DC mode   86%  88% 87%  89% 
    Battery          Standard model machine 
        
    Battery type 12V9AH    
    Quantity   20(18-20
    Adjustable)
     20*2 (18-20
    Adjustable)
     20*2 (18-20
    Adjustable)
    20*3 (18-20
    Adjustable)
    Standard charging time  9 hours charge to 90%  
    The maximum charge current  1A 2A   4A 
    Charging voltage 273VDC±1%  (Based on 20 Batteries)
    Long-term model machine     Battery type  Depending on the application provider    
    Quantity  16(192V)  16(192V)    20(240V) 
    The maximum charge current  4A 4A   12A 
    Charging voltage  273VDC±1%  
    (Based on 20 Batteries)  
    Display description LED or lcd   Load size , battery capacity, AC mode,DCmode,bypass mode,
    Fault Indication
    Warning sound
       
    DC node          Every 4 seconds a sound     
     Warning sound                Every 1 second a sound    
       Overload          Every0.5 second a sound        
      Error     Continuous ringing     
      Physical properties        Standard models  Dimension(D*W*H)mm  592*250*576  815*250*826   815*300*1000 
    Net weight(kgs)  82  164   234 
    Long-term models    Dimension(D*W*H)mm   592*250*576   592*250*576    815*250*826   
    Net weight(kgs)   28 40   64 
     Environment       Humidity      20-90% RH @ 0-40°C(No condensation)     
      Noise     <58dB@1Meter <60dB@1Meter    <65dB@1Meter 
    Control Management
      
    Smart RS-232/USB   Support windows ®   2000/2003XP/Vista/2008
    windows®7/8,Linux,Unix,and MAC
    Optional SNMP  Power management support SNMP management and network management